CVEPublished 2026-08-28Modified 2026-09-010 articles on news4 live referencesNVD data

CVE-2026-81517

Vulnerability data via NVD (ingested)

CVSS v3.1
7.5
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS percentile
18
Exploit Prediction Scoring System · top 82% of all CVEs
Description

An unauthenticated party able to reach the port of a MongoDB Connector for BI (mongosqld) instance may generate enough routine connection log activity to exhaust the storage backing the configured log path. When a log write or log rotation operation subsequently fails, the resulting error is not handled and the shared mongosqld process ends, ending service for all connected SQL clients. The process continues to end on startup until an operator restores available storage, and the diagnostic message explaining the condition is not recorded.

Timeline
Published 2026-08-28
Modified 2026-09-01

External references

Search for exposed instances

Shodan + Censys queries derived from NVD's CPE data. The vuln tag catches assets Shodan has explicitly linked to this CVE; the product / banner fingerprints find exposed instances even when the vuln tag was never applied (which is common). Live host counts are a Premium feature.

More intel sources (5)

Known PoCs on GitHub

No public proof-of-concept repositories found for CVE-2026-81517 on GitHub.
We haven't classified any articles referencing CVE-2026-81517 yet. The external references above still apply.