CVE-2026-80156
Vulnerability data via NVD (ingested)
Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a path traversal vulnerability in the web management portal upload endpoint that allows authenticated attackers to write arbitrary data to any location on the device's filesystem, leading to remote code execution. The upload filename validation strips backslash characters but does not subsequently check for forward slashes when a backslash is detected; by supplying a filename containing both characters an attacker writes outside the intended upload directory to any writable path. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices.
External references
Search for exposed instances
Shodan + Censys queries derived from NVD's CPE data. The vuln tag catches assets Shodan has explicitly linked to this CVE; the product / banner fingerprints find exposed instances even when the vuln tag was never applied (which is common).
More intel sources (5)
vuln:CVE-2026-80156vulnerabilities.cve_id: CVE-2026-80156CVE-2026-80156CVE-2026-80156"CVE-2026-80156" exploit -site:nvd.nist.gov